UFOA1=NONE, BUFTOP=DISABLE, DEBUGRUN=DISABLE, CNTPRESC=DIV1, UFOA0=NONE, REPMODE=FREE, CNTTOPEN=DISABLE
No Description
REPMODE | Repeat Mode 0 (FREE): When started, the LETIMER counts down until it is stopped by software 1 (ONESHOT): The counter counts REP0 times. When REP0 reaches zero, the counter stops 2 (BUFFERED): The counter counts REP0 times. If REP1 has been written, it is loaded into REP0 when REP0 reaches zero, otherwise the counter stops 3 (DOUBLE): Both REP0 and REP1 are decremented when the LETIMER wraps around. The LETIMER counts until both REP0 and REP1 are zero |
UFOA0 | Underflow Output Action 0 0 (NONE): LETIMERn_OUT0 is held at its idle value as defined by OPOL0 1 (TOGGLE): LETIMERn_OUT0 is toggled on CNT underflow 2 (PULSE): LETIMERn_OUT0 is held active for one LETIMER0 clock cycle on CNT underflow. The output then returns to its idle value as defined by OPOL0 3 (PWM): LETIMERn_OUT0 is set idle on CNT underflow, and active on compare match with COMP1 |
UFOA1 | Underflow Output Action 1 0 (NONE): LETIMERn_OUT1 is held at its idle value as defined by OPOL1 1 (TOGGLE): LETIMERn_OUT1 is toggled on CNT underflow 2 (PULSE): LETIMERn_OUT1 is held active for one LETIMER0 clock cycle on CNT underflow. The output then returns to its idle value as defined by OPOL1 3 (PWM): LETIMERn_OUT1 is set idle on CNT underflow, and active on compare match with COMP1 |
OPOL0 | Output 0 Polarity |
OPOL1 | Output 1 Polarity |
BUFTOP | Buffered Top 0 (DISABLE): TOP is only written by software 1 (ENABLE): TOP is set to TOPBUFF value when REP0 reaches 0 |
CNTTOPEN | Compare Value 0 Is Top Value 0 (DISABLE): The top value of the LETIMER is 16777215 (0xFFFFFF) 1 (ENABLE): The top value of the LETIMER is given by TOP |
DEBUGRUN | Debug Mode Run Enable 0 (DISABLE): LETIMER is frozen in debug mode 1 (ENABLE): LETIMER is running in debug mode |
CNTPRESC | Counter prescaler value 0 (DIV1): CLK_CNT = (LETIMER LF CLK)/1 1 (DIV2): CLK_CNT = (LETIMER LF CLK)/2 2 (DIV4): CLK_CNT = (LETIMER LF CLK)/4 3 (DIV8): CLK_CNT = (LETIMER LF CLK)/8 4 (DIV16): CLK_CNT = (LETIMER LF CLK)/16 5 (DIV32): CLK_CNT = (LETIMER LF CLK)/32 6 (DIV64): CLK_CNT = (LETIMER LF CLK)/64 7 (DIV128): CLK_CNT = (LETIMER LF CLK)/128 8 (DIV256): CLK_CNT = (LETIMER LF CLK)/256 |